Publications
Department of Medicine faculty members published more than 3,000 peer-reviewed articles in 2022.
2023
2023
2023
2023
2023
2023
BACKGROUND
Integrating support persons into maternity care, such as making them feel welcome or providing them with information, is positioned to increase support for women and improve birth outcomes. Little quantitative research has examined what support women need and how the healthcare system currently facilitates support for women. We introduce the Person-Centered Integration of Support Persons (PC-ISP) concept, based on a review of the literature and propose four PC-ISP domains-Welcoming environment, Decision-making support, Provision of information and education and Ability to ask questions and express concerns. We report on women's preferences and experiences of PC-ISP.
METHODS
We developed PC-ISP measures based on the literature and applied these in a facility-based survey with 1,138 women after childbirth in six health facilities in Nairobi and Kiambu counties in Kenya from September 2019 to January 2020.
RESULTS
We found an unmet need for integrating support persons during childbirth. Between 73.6 and 93.6% of women preferred integration of support persons during maternity care, but only 45.3-77.9% reported to have experienced integration. Women who reported having a male partner support person reported more PC-ISP experiences (B0.13; 95% CI 0.02, 0.23) than those without. Employed women were more likely to report having the opportunity to consult support persons on decisions (aOR1.26; 95% CI 1.07, 1.50) and report that providers asked if support persons should be informed about their condition and care (aOR1.29; 95% CI 1.07, 1.55). Women with more providers attending birth were more likely to report opportunities to consult support persons on decisions (aOR1.53; 95% CI 1.09, 2.15) and that support persons were welcome to ask questions (aOR1.84, 95% CI 1.07, 2.54).
CONCLUSIONS
Greater efforts to integrate support persons for specific roles, including decision-making support, bridging communication and advocacy, are needed to meet women's needs for support in maternity care.
View on PubMed2023
Transcatheter aortic valve replacement (TAVR) generates significant debris, and strategies to mitigate cerebral embolization are needed. The novel Emboliner embolic protection catheter (Emboline, Inc., Santa Cruz, California) is designed to capture all particles generated during TAVR. This first-in-human study sought to assess the safety and feasibility of the device and to characterize the distribution and histopathology of the debris generated during TAVR. The SafePass 2 study was a prospective, nonrandomized, multicenter, single-arm investigation of the Emboliner device. Primary end points included 30-day major adverse cardiac and cerebrovascular events (MACCE) and technical performance. Computed tomography angiography was analyzed by an independent core laboratory, and filters were sent for histopathology of captured debris. Predictors of particle number were identified using >150 µm and >500 µm size thresholds. Of 31 subjects enrolled, technical success was 100%, and 30-day MACCE was 6.5% (2 cerebrovascular accidents, with 1 attributed to subtherapeutic dosing of rivaroxaban along with atrial fibrillation and the other to possible previous small ischemic strokes on magnetic resonance imaging; neither MACCE event had a causal relation to the Emboliner). All filters contained debris, with a median of 191.0 particles >150 µm and 14.0 particles >500 µm. Histopathology revealed mostly acute thrombus and valve or arterial tissue with lesser amounts of calcified tissue. A history of atrial fibrillation predicted a greater number of particles >500 µm (p = 0.0259) and its presence on admission was associated with 4.1 times more particles >150 µm (p = 0.0130) and 8.1 times more particles >500 µm (p = 0.0086). Self-expanding valves were associated with twice the number of particles >150 µm (p = 0.0281). TASK score was positively correlated with number of particles >500 µm (p = 0.0337). The Emboliner device was safe and feasible. Emboli after TAVR appear more numerous than previously documented. Atrial fibrillation, higher TASK score, and self-expanding valve use conferred higher embolic burden. Notably, none of the tested computed tomography angiography features were able to identify with higher embolic risk. Larger-scale studies are needed to identify high-risk patients for selective embolic protection device use.
View on PubMed2023
2023