BACKGROUND AND AIMS
Gastric variceal bleeding (GVB) is associated with high morbidity and mortality. EUS-guided coil and cyanoacrylate (CYA) injection (EUS-CCI) has been shown to be an effective therapy in acute bleeding and secondary prophylaxis; however, there is a paucity of data on primary prophylaxis.
METHODS
In this single-center observational study, adult patients with high-risk gastric varices (GV; size >10 mm or cherry red spot) without prior bleeding underwent EUS-CCI for the primary prophylaxis of GVB between June 2009 and December 2019. The primary outcome was post-treatment GVB.
RESULTS
Eighty patients with a mean variceal size of 22.5 ± 9.4 mm and a mean length of follow-up of 3.0 ± 2.4 years were included. The etiology of portal hypertension was cirrhosis in 71 patients (88.7%) and noncirrhotic in 9 (11.3). The mean model for end-stage liver disease score was 12.3 ± 3.7 in patients with cirrhosis. The mean coil number was 1.5 (range, 1-3) and mean glue volume injected 2 mL (range, .5-5). Technical success was achieved in 100%, 96.7% had EUS confirmation of GV obliteration, and 67.7% were obliterated with 1 treatment session. Post-treatment GVB occurred in 2 patients (2.5%) and adverse events in 4 (4.9%). No deaths related to GVB occurred, and emergent transjugular intrahepatic shunts were not needed during the follow-up period.
CONCLUSIONS
In patients with high-risk GV, EUS-CCI for primary prophylaxis is highly effective at preventing GVB with a low rate of adverse events. Primary prophylaxis of high-risk GV with coil and CYA glue injection should be considered in centers with the appropriate expertise.
View on PubMed2021
2021
2021
2021
BACKGROUND
Quantitative cardiovascular magnetic resonance T1-mapping is increasingly used for myocardial tissue characterization. However, the lack of standardization limits direct comparability between centers and wider roll-out for clinical use or trials.
PURPOSE
To develop a quality assurance (QA) program assuring standardized T1 measurements for clinical use.
METHODS
MR phantoms manufactured in 2013 were distributed, including ShMOLLI T1-mapping and reference T1 and T2 protocols. We first studied the T1 and T2 dependency on temperature and phantom aging using phantom datasets from a single site over 4 years. Based on this, we developed a multiparametric QA model, which was then applied to 78 scans from 28 other multi-national sites.
RESULTS
T1 temperature sensitivity followed a second-order polynomial to baseline T1 values (R > 0.996). Some phantoms showed aging effects, where T1 drifted up to 49% over 40 months. The correlation model based on reference T1 and T2, developed on 1004 dedicated phantom scans, predicted ShMOLLI-T1 with high consistency (coefficient of variation 1.54%), and was robust to temperature variations and phantom aging. Using the 95% confidence interval of the correlation model residuals as the tolerance range, we analyzed 390 ShMOLLI T1-maps and confirmed accurate sequence deployment in 90%(70/78) of QA scans across 28 multiple centers, and categorized the rest with specific remedial actions.
CONCLUSIONS
The proposed phantom QA for T1-mapping can assure correct method implementation and protocol adherence, and is robust to temperature variation and phantom aging. This QA program circumvents the need of frequent phantom replacements, and can be readily deployed in multicenter trials.
View on PubMed2021