Publications
Department of Medicine faculty members published more than 3,600 peer-reviewed articles in 2024.
2021
2021
2021
2021
2021
Immunotherapies have greatly expanded the armamentarium of cancer-directed therapies in the past decade, allowing the immune system to recognize and fight cancer. Immune checkpoint inhibitors (ICIs), in particular, have revolutionized cancer treatment and have demonstrated survival benefit in numerous types of cancer. These monoclonal antibodies increase anti-cancer immunity by blocking down-regulators of adaptive immunity, including cytotoxic T lymphocyte-associated protein 4 (CTLA-4), programmed cell death protein 1 (PD-1), and its ligand (PD-L1), resulting in anti-tumor activity. As ICIs increase immune system activation, they can cause a wide range of inflammatory side effects, termed immune-released adverse events. Though these toxicities can affect nearly any organ, the most fatal toxicity is myocarditis. Here, we discuss the diverse spectrum of cardiovascular toxicities associated with ICI use. In addition, we provide insight and future directions on mechanisms and treatments for immune-related adverse events (irAEs) involving the myocardium, pericardium, vasculature, and conduction system.
View on PubMed2021
BACKGROUND
Transplant candidates may gain an advantage by traveling to receive care at a transplant center that may have more favorable characteristics than their local center. Factors associated with longer travel distance for transplant care and whether the excess travel distance (ETD) is associated with access to transplantation or with graft failure are unknown.
METHODS
This study of adults in the United States wait-listed for kidney transplantation in 1995-2015 used ETD, defined as distance a patient traveled beyond the nearest transplant center for initial waiting list registration. We used linear regression to examine patient and center characteristics associated with ETD and Fine-Gray models to examine the association between ETD (modeled as a spline) and time to deceased or living donor transplantation or graft failure.
RESULTS
Of 373,365 patients, 11% had an ETD≥50 miles. Traveling excess distance was more likely among patients who were of non-Black race or those whose nearest transplant center had lower annual living donor transplant volume. At an ETD of 50 miles, we observed a lower likelihood of deceased donor transplantation (subhazard ratio [SHR], 0.85; 95% confidence interval [95% CI], 0.84 to 0.87) but higher likelihood of living donor transplantation (SHR, 1.14; 95% CI, 1.12 to 1.16) compared with those who received care at their nearest center. ETD was weakly associated with higher risk of graft failure.
CONCLUSIONS
Patients who travel excess distances for transplant care have better access to living donor but not deceased donor transplantation and slightly higher risk of graft failure. Traveling excess distances is not clearly associated with better outcomes, especially if living donors are unavailable.
View on PubMed2021
PURPOSE
To develop and evaluate a high spatial resolution (1.25 × 1.25 mm ) spiral first-pass myocardial perfusion imaging technique with whole-heart coverage at 3T, to better assess transmural differences in perfusion between the endocardium and epicardium, to quantify the myocardial ischemic burden, and to improve the detection of obstructive coronary artery disease.
METHODS
Whole-heart high-resolution spiral perfusion pulse sequences and corresponding motion-compensated reconstruction techniques for both interleaved single-slice (SS) and simultaneous multi-slice (SMS) acquisition with or without outer-volume suppression (OVS) were developed. The proposed techniques were evaluated in 34 healthy volunteers and 8 patients (55 data sets). SS and SMS images were reconstructed using motion-compensated L1-SPIRiT and SMS-Slice-L1-SPIRiT, respectively. Images were blindly graded by 2 experienced cardiologists on a 5-point scale (5, excellent; 1, poor).
RESULTS
High-quality perfusion imaging was achieved for both SS and SMS acquisitions with or without OVS. The SS technique without OVS had the highest scores (4.5 [4, 5]), which were greater than scores for SS with OVS (3.5 [3.25, 3.75], P < .05), MB = 2 without OVS (3.75 [3.25, 4], P < .05), and MB = 2 with OVS (3.75 [2.75, 4], P < .05), but significantly higher than those for MB = 3 without OVS (4 [4, 4], P = .95). SMS image quality was improved using SMS-Slice-L1-SPIRiT as compared to SMS-L1-SPIRiT (P < .05 for both reviewers).
CONCLUSION
We demonstrated the successful implementation of whole-heart spiral perfusion imaging with high resolution at 3T. Good image quality was achieved, and the SS without OVS showed the best image quality. Evaluation in patients with expected ischemic heart disease is warranted.
View on PubMed