Publications
Department of Medicine faculty members published more than 3,600 peer-reviewed articles in 2024.
2017
2017
2017
2017
BACKGROUND
Recent studies have suggested that non-definitive patterns on high-resolution CT (HRCT) scan provide sufficient diagnostic specificity to forgo surgical lung biopsy in the diagnosis of idiopathic pulmonary fibrosis (IPF). The objective of this study was to determine test characteristics of non-definitive HRCT patterns for identifying histopathological usual interstitial pneumonia (UIP).
METHODS
Patients with biopsy-proven interstitial lung disease (ILD) and non-definitive HRCT scans were identified from two academic ILD centres. Test characteristics for HRCT patterns as predictors of UIP on surgical lung biopsy were derived and validated in independent cohorts.
RESULTS
In the derivation cohort, 64/385 (17%) had possible UIP pattern on HRCT; 321/385 (83%) had inconsistent with UIP pattern. 113/385 (29%) patients had histopathological UIP pattern in the derivation cohort. Possible UIP pattern had a specificity of 91.2% (95% CI 87.2% to 94.3%) and a positive predictive value (PPV) of 62.5% (95% CI 49.5% to 74.3%) for UIP pattern on surgical lung biopsy. The addition of age, sex and total traction bronchiectasis score improved the PPV. Inconsistent with UIP pattern demonstrated poor PPV (22.7%, 95% CI 18.3% to 27.7%). HRCT pattern specificity was nearly identical in the validation cohort (92.7%, 95% CI 82.4% to 98.0%). The substantially higher prevalence of UIP pattern in the validation cohort improved the PPV of HRCT patterns.
CONCLUSIONS
A possible UIP pattern on HRCT has high specificity for UIP on surgical lung biopsy, but PPV is highly dependent on underlying prevalence. Adding clinical and radiographic features to possible UIP pattern on HRCT may provide sufficient probability of histopathological UIP across prevalence ranges to change clinical decision-making.
View on PubMed2017
2017
PURPOSE
Being transgender is associated with numerous health disparities, and transgender individuals face mistreatment and discrimination in healthcare settings. At the same time, healthcare professionals report inadequate preparation to care for transgender people, and patients often have to teach their own medical providers about transgender care. Our study aimed to evaluate the impact of an elective course for health profession students in transgender health that was implemented to address these gaps in provider knowledge.
METHODS
Students participated in a 10-session, lunch-hour elective course during the spring of 2015. To evaluate impact, course participants completed pre-, immediately post-, and 3-month postcourse questionnaires, including a previously validated nine-item transphobia scale, to determine the course's effect on knowledge, attitudes, and beliefs about transgender health.
RESULTS
Forty-six students completed the pre- and immediately postelective questionnaire (74% response rate). Compared with pre-elective surveys, immediately postelective scores demonstrated increased knowledge in most domains and reduced transphobia. Specific knowledge domains with improvements included terminology, best practices for collecting gender identity, awareness of the DSM-V gender dysphoria diagnosis, medications used for gender affirmation, and relevant federal policies. A previously validated transphobia scale was found to have good reliability in the current sample.
CONCLUSION
This elective course led to positive short-term changes in measures of multiple knowledge domains and reduced measures of transphobia among health profession students. Further study is needed to assess the long-term impact. Our methods and findings, including the demonstration of reliability of a previously validated nine-item transphobia scale, serve as formative data for the future development of theory-based transgender medicine curricula and measures.
View on PubMed2017
2017
2017
2017
OBJECTIVES
To investigate how the two main electronic (e-) cigarette solvents-propylene glycol (PG) and glycerol (GL)-modulate the formation of toxic volatile carbonyl compounds under precisely controlled temperatures in the absence of nicotine and flavor additives.
METHODS
PG, GL, PG:GL = 1:1 (wt/wt) mixture, and two commercial e-cigarette liquids were vaporized in a stainless steel, tubular reactor in flowing air ranging up to 318°C to simulate e-cigarette vaping. Aerosols were collected and analyzed to quantify the amount of volatile carbonyls produced with each of the five e-liquids.
RESULTS
Significant amounts of formaldehyde and acetaldehyde were detected at reactor temperatures ≥215°C for both PG and GL. Acrolein was observed only in e-liquids containing GL when reactor temperatures exceeded 270°C. At 318°C, 2.03±0.80 μg of formaldehyde, 2.35±0.87 μg of acetaldehyde, and a trace amount of acetone were generated per milligram of PG; at the same temperature, 21.1±3.80 μg of formaldehyde, 2.40±0.99 μg of acetaldehyde, and 0.80±0.50 μg of acrolein were detected per milligram of GL.
CONCLUSIONS
We developed a device-independent test method to investigate carbonyl emissions from different e-cigarette liquids under precisely controlled temperatures. PG and GL were identified to be the main sources of toxic carbonyl compounds from e-cigarette use. GL produced much more formaldehyde than PG. Besides formaldehyde and acetaldehyde, measurable amounts of acrolein were also detected at ≥270°C but only when GL was present in the e-liquid. At 215°C, the estimated daily exposure to formaldehyde from e-cigarettes, exceeded United States Environmental Protection Agency (USEPA) and California Office of Environmental Health Hazard Assessment (OEHHA) acceptable limits, which emphasized the need to further examine the potential cancer and non-cancer health risks associated with e-cigarette use.
View on PubMed